SPECIFIC EQUIPMENT COMPANY
Standard Reverse Osmosis Watermaker Models and Specifications for Land Based Applications
|
Models |
100m³ |
150m³ |
200m³ |
300m³ |
400m³ |
600m³ |
1000m³ |
1500m³ |
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Water Flow |
1.16 |
1.74 |
2.32 |
3.47 |
4.63 |
6.94 |
11.6 |
17.7 |
|
|
LPS-[USGPM] |
[18.4] |
[28] |
[37] |
[55] |
[73] |
[110] |
[184] |
[280] |
|
|
|
|
|
|
|
|
|
|
|
|
|
Feed Water Flow |
3.75 |
5.68 |
6.62 |
10.22 |
13.18 |
18.93 |
29 |
44 |
|
|
LPS-[USGPM] |
[59.4] |
[90] |
[105] |
[162] |
[209] |
[300] |
[459] |
[700] |
|
|
|
|
|
|
|
|
|
|
|
|
|
Reject Water Flow |
2.59 |
3.91 |
4.29 |
6.75 |
8.58 |
11.99 |
17.3 |
26.5 |
|
|
LPS-[USGPM] |
[41] |
[62] |
[68] |
[107] |
[136] |
[190] |
[275] |
[420] |
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating Pressure *PSI |
845 |
847 |
840 |
855 |
817 |
871 |
882 |
882 |
|
|
Product Water Quality *PPM |
<250 |
<250 |
<250 |
<250 |
<250 |
<250 |
<250 |
<250 |
|
|
Energy consumption no energy recovery* BHP |
32.5 |
49.4 |
57.1 |
89.8 |
110.7 |
170 |
281 |
398 |
|
|
Energy consumption w/ energy recovery* BHP |
22.4 |
25.2 |
29.4 |
47.1 |
60.8 |
90 |
164 |
215 |
|
|
*At design conditions of 36,000 ppm seawater @27ºC after 3 years |
|||||||||
For more information or to send a request for quote please contact us at. E-Mail sales
Specific Equipment company
9046 Long Point Rd.
Houston, Texas 77055
Phone (713) 468-9569